Skip to Content
Comalli Group, Inc. Comalli Group, Inc.
Massachusets 413-213-3661
New York 518-418-7594
Massachusetts 413-213-3661
New York 518-418-7594
Review Us
Review Us
Top
Energized Electrical Testing
Massachusetts 413-213-3661
New York 518-418-7594
  • Continuous Improvement

    Each of us comes to work every day looking for creative ways to improve our work, company processes and interaction with others. We are passionate about improving ourselves and those with whom we work through feedback, teaching and coaching.

  • Respect

    We understand that active listening is a sign of respect. We seek to understand other viewpoints before presenting our own. In the Comalli community, there is no place for yelling, insults, threats, bullying, or harassment of any kind. Period. Caring, compassion, and kindness distinguish the Comalli team.

  • Efficiency

    We are tenacious in our pursuit of efficiency, always looking to streamline our products and processes to make our offerings more useful to customers. We are efficient in our interactions with each other, and respectful of each other's time. We simply don't waste time.

Energized Electrical Testing for Massachusetts and Vermont Facilities

Live-System Diagnostics for Commercial & Industrial Electrical Equipment

Many electrical problems only show up while a system is carrying load. A connection that looks fine at rest can run hot under current, and a breaker that seems healthy can show a voltage drop once the facility is running at full demand. Comalli Group, Inc. performs energized electrical testing for commercial and industrial facilities across Massachusetts and Vermont, using calibrated instruments and licensed electricians to measure, record, and document how your system is performing right now.

Want to know what your live electrical system is telling you? Call (413) 213-3661 or contact us online to schedule an energized electrical assessment.

Why Testing Under Load Reveals Problems a Standard Walkthrough Can Miss

A visual inspection only shows what can be seen. Energized testing adds data from the system while it operates, so deviations in voltage, current, temperature, and electrical noise can be identified and documented before they turn into outages or damaged equipment.

Massachusetts and Vermont facilities face conditions that make this kind of testing especially useful. Long, cold winters push heating and process loads higher, humidity swings and freeze-thaw cycles can affect enclosures and connections, and many facilities in both states run electrical equipment installed decades ago in older industrial and mill-era buildings. Testing while the system is live shows how that equipment is holding up under real operating conditions.

Our energized inspections look for conditions such as the following.

  • Hot spots: High-resistance connections and overloaded conductors that generate heat.
  • Voltage irregularities: Readings outside the range your equipment needs to operate properly.
  • Electrical noise: Distortion that can strain sensitive electronics and transformers.
  • Phase problems: Imbalances that raise operating temperatures and shorten equipment life.
  • Early discharge activity: Corona, tracking, and arcing that are not visible to the eye.
Proudly Serving Since 1981 A Legacy of Excellence Learn More

Energized Testing Services Performed by Licensed Electricians

Each test gives a different view of system health, and together they build a more complete picture than any single method can. Our energized services follow NFPA 70E safe work practices and NFPA 70B maintenance recommendations.

True RMS Voltage & Current Readings

We capture and record true RMS voltage and current across your system and compare the results against what your equipment requires. Readings that fall outside the expected range point to underlying issues, and catching them early helps protect equipment and its service life.

Voltage Drop Measurements at Breakers & Contact Points

Voltage drop across circuit breakers and contact surfaces shows whether those components are still passing power efficiently. Excessive drop signals components that are wearing out, which raises both equipment and safety concerns. We record the readings so you can see how they change from one visit to the next.

Thermal Imaging & Ultrasonic Scanning

Infrared thermographic imaging, calibrated to NFPA 70B recommendations, reveals heat patterns from loose connections, overloaded circuits, and failing insulation. Ultrasonic testing listens for corona, tracking, and arcing above the range of human hearing. The two methods complement each other, and each can identify conditions the other may miss.

Continue Reading Read Less
A History of Excellence

Contact Us Today

A member of our team will be in touch shortly to confirm your contact details or address questions you may have.

  • Please enter your first name.
  • Please enter your last name.
  • Please enter your phone number.
    This isn't a valid phone number.
  • Please enter your email address.
    This isn't a valid email address.
  • Please lookup your address.
  • Please make a selection.
  • Please enter a message.
  • By submitting, you agree to receive text messages from Comalli Group, Inc. at the number provided, including those related to your inquiry, follow-ups, and review requests, via automated technology. Consent is not a condition of purchase. Msg & data rates may apply. Msg frequency may vary. Reply STOP to cancel or HELP for assistance. Acceptable Use Policy